OMEGA Laser Facility > Documentation > Volume III Subsystem and Component Maintenance > Section 5 Optomechanical
OMEGA System Operations Manual - Volume III -- Subsystem and Component Maintenance (S-AA-M-014)
Front
Matter - Maintenance Index & Schedules - S-OM-P-030
Subsystem Actions Requiring Shots:
S-SM-P-242: HED Calibration Check
S-SM-P-243: HED Calibration (Complete)
S-SM-P-244: FCC Tuning Scan
S-SM-P-245: FCC Tuning Check
S-SM-P-246: HED Burn
S-SM-P-247: D Burn
S-SM-P-248: UV Focus Scan
S-SM-P-249: Reference Best Focus
Subsystem Actions Without Shots :
S-SM-P-250: Beam Timing Run
S-SM-P-251: OMEGA Transport Instrumentation System (OTIS)
S-SM-P-252: Blast Window Assembly (BWA) UV Transport
S-SM-P-253: Primary Pick-Off (PPO) / DPR Transmission
S-SM-P-254: Measure SG4 DPP Transmission
S-SM-P-255: Full System Auto Balance
S-SM-P-256: Set Splits with Roving Diagnostic
S-SM-P-257: Calibrate Calorimeters - Check
S-SM-P-258: Calibrate Calorimeters - Calibration Series
S-SM-P-333: Two State Control Module
IR Alignment Procedures:
S-SM-P-259: Check Mirror Wavefront Quality
S-SM-P-260: Leg Collimation Check
S-SM-P-261: Re-Align A-Rods
S-SM-P-262: System Crosshair to A-Out Crosshair
S-SM-P-263: A-Out Crosshair to B-In Crosshair
S-SM-P-264: Check/Adjust Alignment: B-Split
S-SM-P-265: Check Alignment at D-Split Input Fiducials
S-SM-P-266: Update F-ASP Coarse Pointing References
S-SM-P-267: Check/Correct Alignment of the Stage F Prisms
S-SM-P-268: Check SSA Alignment, Level
S-SM-P-269: Check Alignment of Spatial Filters
S-SM-P-270: Check Level of FCC Rails
S-SM-P-271: Spatial Filters - Check Leakage Rate
S-SM-P-272: Spatial Filters - Mechanical Checks
S-SM-P-273: Check Spatial Filter PHM Electrical Connections
S-SM-P-274: Beamline Collimation Check
S-SM-P-275: Replace Retro Burn Paper
S-SM-P-276: Check Fixed Optic Lockdowns on IRAT
S-SM-P-277: Check Fixed Optic Lockdowns on A-Split
S-SM-P-278: Check Fixed Optic Lockdowns on B-Split
S-SM-P-279: Check Fixed Optic Lockdowns on C-Splits
S-SM-P-280: Check Fixed Optic Lockdowns on D-Splits
S-SM-P-281: Manual Knife-Edge Pinholes
S-SM-P-282: Remote Knife-Edge D, E, F Pinhole Evaluation
S-SM-P-283: Check Knife-Edge Diagnostic Calibration
S-SM-P-284: LPI Alignment Check
S-SM-P-285: Check D-Shutter Limit Switches
S-SM-P-286: Reference Crystaks using Second Tripler Alignment Diagnostic (STAD)
UV Alignment Procedures:
S-SM-P-287: Check/Align HED Spatial Filters
S-SM-P-288: Check/Adjust UV Centering DPR In / DPR Out
S-SM-P-289: FLAS Retro Check
S-SM-P-290: UVAT Alignment Check
S-SM-P-291: UVAT Full Alignement
S-SM-P-292: Clean and Inspect UVAT Optics
S-SM-P-293: Pump Diode Replacement for UVAT I & UVAT II
S-SM-P-294: UVAT Collimation Check
S-SM-P-295: Clean UVAT I Particulate Filter
S-SM-P-296: Check / Adjust UVDT Alignment
S-SM-P-297: Operate & Check Out UVAT I & UVAT II
S-SM-P-298: Calorimeter Seal Check
S-SM-P-299: Check HED Coolant Level
S-SM-P-300: Check Burn Paper on Back of F-Cals
S-SM-P-301: Verify Alignment of FLAS Retro Fixture
S-SM-P-302: Check UVAT II Water Level
IRAT Procedures:
S-SM-P-303: IRAT Alignment Check
S-SM-P-304: IRAT Full Alignment
S-SM-P-305: Clean and Inspect Optics
Long Path Length Adjuster Procedures:
S-SM-P-306: Inspect PLAS
S-SM-P-307: Check Mounting Pad Lock-Downs
S-SM-P-308: PLAS Mirror Alignment Checks
S-SM-P-309: D-Split Mirrors - Coordinate Verification
Focus Lens Procedures:
S-SM-P-310: FLAS Encoder Mechanical Check
S-SM-P-311: Replace Compensation Springs
S-SM-P-312: Exercise FLAS Springs
S-SM-P-313: Support BWA Change
S-SM-P-314: Support Focus Lens Change
S-SM-P-315: Support DPP Change
Periscope Mirror Assembly Procedures:
S-SM-P-316: Inspect/Lubricate RAPIDTRAK Ball Screw
S-SM-P-317: Check/Replenish Gearbox Oil
S-SM-P-318: Inspect & Lubricate Kinematic Mount Surfaces
S-SM-P-319: Lubricate Air Cylinder Clevis Pins
S-SM-P-320: Check Pneumatic Filters
S-SM-P-321: Inspect Rails
S-SM-P-322: Check Fasteners
S-SM-P-323: Change Gearbox Oil
S-SM-P-324: Change DeMag Trolley Gearbox Oil
S-SM-P-325: Verify Function of Safety Features
S-SM-P-326: X Travel Calibration
ASP Procedures:
S-SM-P-327: Inspect and Verify ASP Functionality in the A and C Stages
S-SM-P-328: Verify Function and Imaging
S-SM-P-329: Inspect Crosshair Stops
P510 Procedures:
S-SM-P-315: Clean P510 Streak Camera Optics
S-SM-P-330: P510 Water Chiller Level
HEDVAC Procedures:
S-SM-P-331: HEDVAC System Maintenance
S-SM-P-332: HEDVAC Pump Maintenance